Thermally Conductive Vibration Isolation for
Cryocoolers (TCVIS)

AFRL Phase II SBIR,
Topic AF96-075; prototype demonstrated 7/99
- Vibration
cancellation uses compact six-axis electromagnetic actuators
- 100:1
reduction goal for cryocooler drive axis
- 20:1 reduction goal for cross-axis
- Heat transfer
from cryocooler uses flexible carbon fiber strap; ten times more
efficient than copper
- Six axis
actuator system successfully tested at NIST with axial/radial
reductions of:
- Drive
frequency > -40 dB (>100:1)
- First four harmonics > -20 dB
- System
developed jointly by CSA Engineering and TAI.
We also developed a single-axis actuator
as a spin-off technology:
Compact
& inexpensive system!
- Drive Frequency
> -42 dB
- First four harmonics -20 to -40 dB
- Fifth through tenth harmonic -16dB avg.